Evalm
Dual Digital Thermostat Temperature Controller with Two Relay Outputs for Incubator Heating & Cooling, XK-W1088 AC110-220V
Dual Digital Thermostat Temperature Controller with Two Relay Outputs for Incubator Heating & Cooling, XK-W1088 AC110-220V
Estimated Delivery: -
Couldn't load pickup availability
Perfect for Various Applications: Ideal for household, institutional, and industrial heating and cooling applications.
Features
- Heating or cooling control
- Red and blue dual LED display
- Independent dual-way temperature controller
- Temperature display resolution: 0.1°C
- Direct power output
- High/low temperature alarm support and power loss parameter retention
- Suitable for home temperature control, farms, cold storage, greenhouses, aquariums, etc.
Specifications
- Display Type: Digital
- Material: ABS+PCB
- Style: Standing Station
- Temperature Sensor: NTC 10K
- Sensor Length: 1.0m
- Temperature Measuring Range: -55°C to 120°C / -66°F to 248°F
- Resolution: 0.1°C
- Accuracy: ±1°C
- Power Supply: 110-220VAC 50/60Hz, 12V DC, 24V DC (Choose power supply when ordering)
- Power Consumption: <3W
- Storage Temperature: -30°C to 75°C
- Relative Humidity: 20% to 85% (No condensate)
- Relay Contact Capacity: Two Relay Max 10A, Direct Output
- Item Size: 7.5 x 5.5 x 3.1 cm / 2.95 x 2.16 x 1.22 in
- Item Weight: 80g / 2.82oz
Settings and Adjustments
Set Startup Temperature: Press the "up" button once to display the starting temperature. Long press for 3 seconds to set the desired temperature using the up and down keys.
Set Stop Temperature: Press the button once to display the stop temperature. Long press for 3 seconds to set the desired temperature using the up and down keys.
Entering Setting Mode: Press "Up 1" and "Up 2" buttons simultaneously.
Restore Factory Settings: Press "Down 1" and "Down 2" buttons simultaneously to restore to factory settings.
Temperature Correction: Press "Up 1" and "Down 1" for 3 seconds. Correct positive value using measured value + corrected value (use same method for group 2 temperature correction).
Note:
- Heating Mode: Start temperature < Stop temperature
- Cooling Mode: Start temperature > Stop temperature
Parameter Settings
| Code | Function | Set Range | Default |
|---|---|---|---|
| P0 | Compressor 1 delay time | 0-60min | 0min |
| P1 | Compressor 2 delay time | 0-60min | 0min |
| P2 | High temperature alarm value | -55 to 120°C / -67 to 248°F | 120°C / 248°F |
| P3 | Low temperature alarm value | -55 to 120°C / -67 to 248°F | -55°C / -67°F |
Package List
- 1 x Temperature Controller
- 2 x Waterproof Sensor